Biological Safety Cabinet Class II B2 LE-BSC401 is designed with 100% exhaust airflow and leak-free construction. It is equipped with a high-performance blower that ensures consistent and contamination-free operation. Integrated air velocity monitoring system maintains real-time control over inflow and downflow. Built-in pressure sensor displays negative pressure differentials accurately on a large LCD. Our Biological Safety Cabinet Class II B2 is designed to provide operator, product, and environmental protection in environments where recirculation of filtered air is prohibited.
FunctionImplementationTotal exhaust containment100% external exhaust without air recirculationOperator protection validation≤10 CFU impaction sampler performanceProduct sterility controlISO 14644.1 Class 3 clean downflow airCross contamination limitation≤2 CFU cross contamination performance
| Type of BSC | Class Ⅱ Type B2 |
| Airflow Mode | 100% Exhaust |
| Exhaust Direction | Top Exhaust |
| Average Inflow Velocity | 0.53m/s |
| Average Downflow Velocity | 0.35m/s |
| Inflow Airflow Volume | 1141m3/h |
| Downflow Airflow Volume | 798m3/h |
| Exhaust Airflow Volume | 1141m3/h |
| Velocity Meter Accuracy | 0.001m/s |
| Cleanliness | ULPA: Class 3(ISO 14644.1); Class 100 (Fed 209E) |
| Filter Typical Efficiency | Greater Than 99.999% at 0.1 to 0.3 Micron, ULPA as per IEST-RP-CC001.3 USA |
| Total Colony in Impaction Sampler (Operator Protection) | ≤10CFU/Time |
| Total Colony in Slit Type Sampler (Operator Protection) | ≤5CFU/Time |
| Total Colony in Culture Dish (Product Protection) | ≤5CFU/Time |
| Total Colony in Culture Dish (Cross Contamination) | ≤2CFU/Time |
| Personnel Protection Test | KI-Discus Containment and Microbiological Testing are Performed |
| Blower | AC |
| Downflow Filter | ULPA |
| Exhaust Filter | ULPA |
| Main Body | 1.2mm (xxx'') 18 Gauge Electro-Galvanized Steel with White Oven-Baked Powder-Coated Finish |
| Work Zone | 1.5mm (xxx'') 16 Gauge Stainless Steel, Type304, Single-Piece or 3-Piece |
| Side Walls | 1.5mm (Xxx'') 16 Gauge Stainless Steel, Type304 |
| Sash Glass Thickness | 5mm |
| Sash Glass Type | Tempered Glass, UV-Proof |
| Sash Window Working Opening | 180mm |
| Sash Maximum Opening | 530mm |
| Fluorescent Light Intensity | ≥700lux |
| RMS | ≤3um |
| Sound Emission (dBA) | ≦65dBA |
| Display | 7 Inches Touch Screen |
| UV Timer | Yes |
| Main Power Switch | Yes |
| Alarm Type | Audible + Visual |
| Alarm Function | Inflow Velocity, Downflow Velocity, Sash Height Limit, Filter Blocked, Filter Lifetime Remind |
| Cabinet Full Load Amps (FLA) | 2.2A |
| Power Consumption | 1500W (Excluding External Exhaust Fan) |
| Power Supply | AC220±10%,50/60H |
| Normal Size | 3 Feet |
| Usable Working Area | 0.672m2, 7.23 sq.ft |
| Stand Height | 640mm (Adjustable) |
| Internal Work Area Dimensions | 1000 × 672 × 630mm |
| External Dimensions with Base Stand | 1180 × 790 × 2080mm |
| Packing Dimension | 1310 × 950 × 2220mm |
| Net Weight | 280 Kg |
| Gross Weight | 305 Kg |