Biological Safety Cabinet Class II B2 LE-BSC401

Biological Safety Cabinet Class II B2 LE-BSC401

Biological Safety Cabinet Class II B2 LE-BSC401 is designed with 100% exhaust airflow and leak-free construction. It is equipped with a high-performance blower that ensures consistent and contamination-free operation. Integrated air velocity monitoring system maintains real-time control over inflow and downflow. Built-in pressure sensor displays negative pressure differentials accurately on a large LCD. Our Biological Safety Cabinet Class II B2 is designed to provide operator, product, and environmental protection in environments where recirculation of filtered air is prohibited.

Specifications

Type of BSC Class Ⅱ Type B2
Airflow Mode 100% Exhaust
Exhaust Direction Top Exhaust
Average Inflow Velocity 0.53m/s
Average Downflow Velocity 0.35m/s
Inflow Airflow Volume 1141m3/h
Downflow Airflow Volume 798m3/h
Exhaust Airflow Volume 1141m3/h
Velocity Meter Accuracy 0.001m/s
Cleanliness ULPA: Class 3(ISO 14644.1); Class 100 (Fed 209E)
Filter Typical Efficiency Greater Than 99.999% at 0.1 to 0.3 Micron, ULPA as per IEST-RP-CC001.3 USA
Total Colony in Impaction Sampler (Operator Protection) ≤10CFU/Time
Total Colony in Slit Type Sampler (Operator Protection) ≤5CFU/Time
Total Colony in Culture Dish (Product Protection) ≤5CFU/Time
Total Colony in Culture Dish (Cross Contamination) ≤2CFU/Time
Personnel Protection Test KI-Discus Containment and Microbiological Testing are Performed
Blower AC
Downflow Filter ULPA
Exhaust Filter ULPA
Main Body 1.2mm (xxx'') 18 Gauge Electro-Galvanized Steel with White Oven-Baked Powder-Coated Finish
Work Zone 1.5mm (xxx'') 16 Gauge Stainless Steel, Type304, Single-Piece or 3-Piece
Side Walls 1.5mm (Xxx'') 16 Gauge Stainless Steel, Type304
Sash Glass Thickness 5mm
Sash Glass Type Tempered Glass, UV-Proof
Sash Window Working Opening 180mm
Sash Maximum Opening 530mm
Fluorescent Light Intensity ≥700lux
RMS ≤3um
Sound Emission (dBA) ≦65dBA
Display 7 Inches Touch Screen
UV Timer Yes
Main Power Switch Yes
Alarm Type Audible + Visual
Alarm Function Inflow Velocity, Downflow Velocity, Sash Height Limit, Filter Blocked, Filter Lifetime Remind
Cabinet Full Load Amps (FLA) 2.2A
Power Consumption 1500W (Excluding External Exhaust Fan)
Power Supply AC220±10%,50/60H
Normal Size 3 Feet
Usable Working Area 0.672m2, 7.23 sq.ft
Stand Height 640mm (Adjustable)
Internal Work Area Dimensions 1000 × 672 × 630mm
External Dimensions with Base Stand 1180 × 790 × 2080mm
Packing Dimension 1310 × 950 × 2220mm
Net Weight 280 Kg
Gross Weight 305 Kg

Features

  • Average inflow velocity 0.53 m/s with 1141 m³/h exhaust volume
  • ULPA filtration efficiency ≥99.999% at 0.1–0.3 µm particle size
  • Integrated velocity monitoring with 1×10⁻³ m/s measurement accuracy
  • Type 304 stainless steel work zone with negative pressure monitoring system

Applications

FunctionImplementation
Total exhaust containment100% external exhaust without air recirculation
Operator protection validation≤10 CFU impaction sampler performance
Product sterility controlISO 14644.1 Class 3 clean downflow air
Cross contamination limitation≤2 CFU cross contamination performance

Standard Accessories

  • Fluorescent lamp – 30W × 2
  • Ultraviolet lamp - 30W × 1
  • Receptacle
  • Detachable Base Stand
  • Wheels

Optional Accessories

  • Gas Valve
  • Vacuum Valve
  • Water Valve

Biological Safety Cabinet Class II B2 LE-BSC401

Biological Safety Cabinet Class II B2 LE-BSC401


Related Models Of Biological Safety Cabinet Class II B2

Lab Expo Biological Safety Cabinet Class II B2 supports high-containment laboratory operations where total exhaust and zero air recirculation are required for hazardous biological and chemical handling. This bsc class ii type b2 operates with full exhaust airflow and HEPA filtration to remove contaminated air from the work zone. Digital controls monitor airflow and pressure, while integrated alarms and safety interlocks ensure controlled, compliant containment during critical procedures.