Biological Safety Cabinet Class II A2 56-BSC101

Biological Safety Cabinet Class II A2 56-BSC101

Biological Safety Cabinet is a Class II type A2 safety level 2 enclosed cabinet unit with 70% of the HEPA filtered air recirculated through the cabinet and 30% discharged through an exhaust HEPA filter to the environment. It is used to handle minute quantities of volatile toxic chemicals and trace amounts of radio nucleotides where chemical vapor re-circulation into the work zone is permitted. It meets the requirements for the protection of product, personnel and the environment allowing for the safe handling of pathogens, contaminants or other potentially hazardous materials.

Specifications

Air circulation 70%
Air exhaust 30%
Glass door orientation 10° tilted
Working area 1000 x 650 x 620 mm
Overall dimension 1195 x 720 x 1950 mm
HEPA filter 0.3 micron
Air pressure Vertical negative
Cleaning level 100 level
Ascending wind speed ≥ 0.55 m/s
Descending wind speed ≥ 0.35 m/s
Noise ≤ 58 dB
Half ventilation peak value ≤ 3 µm
Personnel protection CFU ≤ 10
Product protection CFU ≤ 5
Cross contamination CFU ≤ 2
Fluorescent lamp 20 W x 2
UV lamp 20 W x 1
Power AC 220 V / 50 Hz
Air supply filter dimension 955 x 545 x 50 mm
Weight 300 kg

Features

  • 70% internal air recirculation with 30% HEPA-filtered exhaust
  • 0.3 µm HEPA filtration with Class 100 clean level performance
  • Ascending airflow ≥0.55 m/s with descending airflow ≥0.35 m/s
  • Vertical negative pressure chamber with air insulation barrier
  • Stainless steel work zone with microprocessor LCD control system

Applications

FunctionImplementation
Pathogen HandlingClass II A2 containment for bacteria & culture procedures
Low-Volume Toxic Chemical Work70/30 airflow supporting controlled vapor recirculation
Radiolabeled Material ProcessingEnclosed workspace for trace radionucleotide handling
Sterile Sample PreparationHEPA-filtered Class 100 environment for contamination-sensitive tasks
Clinical & Research DiagnosticsNegative pressure cabinet for regulated diagnostic workflows

Related Models Of Class II Biological Safety Cabinet

Lab Expo Class II Biological Safety Cabinet supports controlled containment workflows where regulated airflow and HEPA filtration are required for safe biological handling. This class ii bsc operates with defined inflow and downflow air patterns, offering A2 or B2 configurations with recirculation or total exhaust as specified. Microprocessor controls manage airflow stability and monitoring, while stainless steel work surfaces, negative pressure containment, and integrated alarms ensure controlled, compliant operation for routine laboratory procedures.