High Performance Liquid Chromatograph LE-HPLC101

High Performance Liquid Chromatograph LE-HPLC101 operates at a flow rate of 0.001 to 10.000 mL/min. It offers a wavelength range of 190 to 900 nm for broad-spectrum detection. Equipped with deuterium and tungsten lamp to provide accurate and sensitive analysis. Built-in injection system ensures precise, repeatable sample delivery with multiple injection modes. Our HPLC enables stage-wise temperature control with interval heating and cooling.

Specifications

Pump Type Four Element Infusion Pump with Double Plunger Reciprocating System
Flow Rate 0.001 to 10.000 mL/min (increment 0.001 mL/min)
Flow Accuracy ±0.5% (at 1 mL/min, water)
Flow Precision ≤0.06% RSD
Pressure Range 0 to 10500 psi (72 MPa)
Gradient Accuracy ±0.5%
Gradient Repeatability ≤0.2% SD
Pressure Pulsation ≤1% (at 1 mL/min, water, >10 MPa)
UV Detector Light Source Deuterium Lamp, Tungsten Lamp
Wavelength Range 190 to 900 nm
Wavelength Accuracy ±1 nm
Wavelength Precision ±0.1 nm
Noise ±5.0×10⁻⁶ AU (JJG) / ±3.5×10⁻⁶ AU (ASTM)
Baseline Drift 1×10⁻⁴ AU/hr
Linear Range >5×10⁴ (JJG) / >2.5 AU (ASTM)
Spectral Bandwidth 8 nm
Fluorescence Light Source 150 W Xenon Lamp
Wavelength Range 200–650 nm (up to 900 nm optional)
Detector PMT
Raman SNR >1200
ELSD Light Source 650 nm Semiconductor Laser
Evaporation Temperature Ambient to 130°C
Atomization Temperature Ambient to 56°C
Min Detection Concentration <1 ng
Dynamic Range 10⁴
Refractive Index Range 1.00 to 1.75
Detection Range 0.25 to 512 μRIU
Noise ≤5 nRIU
Temperature Control Off, 30 to 50°C
Column Oven Capacity Holds ≥4 columns (300 mm)
Temperature Control Range Ambient +5°C to 85°C
Temperature Accuracy ±1.0°C
Temperature Stability ±0.1°C
Injection Modes Full loop, Partial loop, μL pickup
Sample Positions ≥108 (1.5 mL vials)
Sample Accuracy ≤0.3% RSD
Sample Residue <0.0025%
Compliance FDA 21 CFR Part 11 / GMP / GLP
Environmental Temperature 15 to 35°C
Environmental Humidity <85%
Power Supply Single phase 220V ±10% 50/60Hz

Features

  • Flow rate 0.001 to 10.000 mL/min with ±0.5% accuracy and ≤0.06% RSD
  • Pressure range up to 10500 psi (72 MPa) with ≤1% pulsation
  • Wavelength range 190 to 900 nm with ±1 nm accuracy
  • Deuterium and tungsten lamps with optional fluorescence and ELSD detection
  • Column oven Ambient +5 C to 85 C with ±0.1 C stability and ≥108 sample positions

Applications

FunctionImplementation
Pharmaceutical analysisHigh pressure gradient control enables compound separation
Food and environmental testingBroad wavelength detection supports multi-component screening
Trace compound quantificationLow noise UV detection enhances sensitivity
Complex mixture profilingMulti-detector compatibility expands analytical capability
Regulatory compliance testingSupports FDA 21 CFR Part 11, GMP and GLP workflows

Standard Accessories

Software

In-line Mobile phase Degasser

C18-2Pcs

Amino column 1pc

Solvent filter 1pc

Filter head 1pc

Filter membrane 1pc