Biological Safety Cabinet 99-BSC100

Biological Safety Cabinet 99-BSC100 features a high-quality ULPA filter that captures over 99.9995% of particles as small as 0.12 μm. It has an inflow velocity of 0.55 m/s and a downflow velocity of 0.35 m/s which maintain a sterile and controlled environment. It utilizes ULPA filtration technology for contaminant removal, offering the highest level of protection for both personnel and samples. Our Biosafety Cabinet has a built-in sterilization function that eliminates biological contamination and keeps the environment sterile.

Specifications

Filtration Efficiency >99.9995% at 0.12μm
Inflow Velocity 0.55 m/s
Downflow Velocity 0.35 m/s
Air Supply and Exhaust Filters ULPA filters
Air Cleanliness ISO 4 Class
Air Direction Top out
Execution Standards YY0569, GB 4793.1, GB/T 18268.1
Personnel Protection Impaction sampler: <10 CFU/time; Slot sampler: <5 CFU/time
Product Protection Culture dish: <5 CFU/time
Cross-contamination Protection Culture dish: <2 CFU/time
Light Size and Quantity 18 W × 1
UV Light Size and Quantity 20 W × 1
Luminance ≥900 LX
Cabinet Materials High-grade steel, lacquered in ivory
Working Area Materials SS304 fully finished
Vibration <5 μm (center of tabletop)
Noise Level <65 dB
Max Power Consumption (with spare socket) 1.65 KW
Rated Power (without spare socket) 0.33 KW
Power Supply 115/230V ±10%, 50/60Hz
Internal Dimensions 1180×580×798 mm
External Dimensions 1300×810×2290 mm
Support Base (with wheels) 1285×710×680 mm
Weight 265 kg

Features

  • ULPA filtration efficiency >99.9995% at 0.12 µm particle size
  • Inflow velocity 0.55 m/s with 0.35 m/s vertical downflow
  • ISO 4 Class air cleanliness with top exhaust configuration
  • Smart 7-inch touchscreen display with airflow monitoring

Applications

FunctionImplementation
Personnel Protection<10 CFU/time impaction sampler validation
Product Sterility Control<5 CFU/time culture dish verification
Cross Contamination Limitation<2 CFU/time separation performance test
Microbiological ProceduresISO 4 classified controlled airflow workspace
Genetic & Pharmaceutical ProcessingULPA-filtered sterile chamber environment

Related Models Of Class II Biological Safety Cabinet

Lab Expo Class II Biological Safety Cabinet supports controlled containment workflows where regulated airflow and HEPA filtration are required for safe biological handling. This class ii bsc operates with defined inflow and downflow air patterns, offering A2 or B2 configurations with recirculation or total exhaust as specified. Microprocessor controls manage airflow stability and monitoring, while stainless steel work surfaces, negative pressure containment, and integrated alarms ensure controlled, compliant operation for routine laboratory procedures.